文章詳目資料

藥物食品分析 MEDLINESCIEScopus

  • 加入收藏
  • 下載文章
篇名 以固相萃取與高效液相層析法鑑定豬肉與雞肉中之泰妙素
卷期 14:1
並列篇名 Determination of Tiamulin Residue in Pork and Chicken by Solid Phase Extraction and HPLC
作者 陳惠章鄭守訓蔡永祥黃登福
頁次 080-083
關鍵字 tiamulinveterinary drughigh performance liquid chromatography chickenpork泰妙素動物用藥高效液相層析儀豬肉雞肉MEDLINEScopusSCIE
出刊日期 200603

中文摘要

本研究係以高效液相層析儀(HPlC)來鑑定雞肉與豬肉中之泰妙素:樣品經由乙腈萃取後,以液液分離純化,最後以正己烷萃取,萃取液經濃縮後,再經過Bond elut C18 萃取匣淨化後以HPlC分析。HPlC之分析管柱為lichrospher 100 RP-18 column (5 μm,4.6 mm I.d. × 250 mm),移動相為80%乙腈與1%碳酸銨(90:10,v/v),偵測波長為210 nm。研究結果得知,當泰妙素之濃度為0.5~8.0 ppm時,直線校正曲線有良好相關係數(R2= 0.9995),而檢測極限為0.025 ppm。添加泰妙素標準品至雞肉與豬肉中,回收率分別為84.3~97.0%與87.9~105.9%。此外,由市場購得之雞肉與豬肉樣品各10件,均未檢出泰妙素。

英文摘要

A high performance liquid chromatography (HPLC) was developed for determining tiamulin residue in chicken and pork.
Samples were extracted with acetonitrile, purified by liquid partition separation, and extracted with n-hexane at last. The n-hexane
extract was concentrated and eluted through a Bond Elut C18 cartridge for HPLC analysis. The HPLC system was performed on
a Lichrospher 100 RP-18 column (5 μm, 4.6 mm I.D. × 250 mm) using a mixture of 80% acetonitrile and 1% ammonia carbonate(90:10, v/v) as mobile phase, and detecting wavelength was set at 210 nm with an UV-Vis detector. The calibration curve (R2 =0.9995) of tiamulin was highly linear at concentrations of 0.5~8.0 ppm, while the detection limit was 0.025 ppm. Recoveries oftiamulin spiked in chicken and pork samples ranged from 84.3~97.0% and 87.9~105.9%, respectively. Each 10 chicken and porksamples sold in retail markets were tested to detect tiamulin, while none of these samples contained tiamulin.

本卷期文章目次