篇名 質量均一性:以打錠操作壓縮條件對於有刻痕錠劑分割之影響作為製造時耐變性評估之一部份
卷期 13:1
並列篇名 Mass Uniformity: Influence of Operational Compression Conditions on Breakability of Scored Tablets as Part of Manufacturing Robustness Evaluation
作者 Spiegeleer, Bart DeVooren, Lieven VanThonissen, ThomasJoye, PhilippeCornelissen, BartLammens, GeertSlegers, Guido
頁次 22-29
關鍵字 刻痕錠劑錠劑分割重量均一性統計管控壓縮確效耐變性開發Scored tabletsTablet breakabilityWeight uniformityStatistical controlCompression validationRobustness developmentMEDLINEScopusSCIE
出刊日期 200503

中文摘要

英文摘要

Dose uniformity is a key quality element of drugs. The purpose of this study was to demonstrate a practical approach to evaluate the breakability robustness as part of the tabletting validation of a scored tablet. The influence of operational compression parameters (speed and force) on the weight variabilities of half- and quarter tablets was investigated using two types of cross-scored round tablets of identical composition but different in size. It was shown for the used veterinary model tablet that manufacturing variation of two compression parameters around the defined target values do not significantly influence the weight variability of the broken tablets. The empirical guidance was also confirmed that for the investigated dose proportional tablets the standard deviation of the broken tabletpart weight is linearly related to the original tablet weight. There exists a strong correlation between the variability of half-tablets and of quarter-tablets: the theoretical model previously presented was refined, demonstrating that the additional variance induced by breaking is a linear function of the break-line length. As a consequence, the standard deviation of half- and quarter-parts of crossscored round tablets, expressed in mass units, will thus remain approximately identical. Hence, the relative standard deviation (RSD) of quarter-tablet weights will nearly double when breaking half-tablets into quarter-tablets.

本卷期文章目次

相關文獻