篇名 Ciprofloxacin藥物酵素連結免疫吸附法殘留檢驗試劑之開發
卷期 42:2、42:2
並列篇名 Development of the Enzyme-linked Immunosorbent Assay Residual Detection Kit for Ciprofloxacin
作者 林毓芬洪紹文陳柏叡鄒禮澤涂青宇張鎮璿何素鵬王渭賢
頁次 73-80
關鍵字 殘留多株抗體酵素連結免疫吸附法環丙氟?酸氟?諾酮類ResiduePolyclonal antibodyELISACiprofloxacinFluoroquinoloneTSCI
出刊日期 200712

中文摘要

本研究目的在於開發直接競爭型酵素?結免疫吸附法,期能?確、簡單及快速檢測禽畜水產品中ciprofloxacin (Cipro)殘?之檢測試劑。實驗結果顯示?用N-hydroxysuccinimide ester法可成功製備Cipro-human serum albumin (HSA)之結合蛋白,同時以相同的方法可以分別成功製備出藥物-bovine serum albumin結合蛋白和藥物-horseradish peroxidase之結合體。另外,?用高效液相層析法(high performance liquid chromatography)搭配紫外光和螢光檢測器可以檢測藥物-HSA結合體。運用所製備之Cipro-HSA之結合蛋白以皮下免疫?西?白兔?次後,可成功誘導產生多株抗體,?價高達65,536倍以上。收集多株抗體並製備成直接競爭型ELISA盤後,在磷酸緩衝液 (PBS)中的最低檢測極限為0.78 ppb,而在牛奶、fetal bovine serum、吳郭魚肉、?肉、雞肉、蝦肉及牛肉中分別為1.08 ppb、1.37 ppb、0.83 ppb、1.1 ppb、0.88 ppb、1.32 ppb 及1.14 ppb,故所開發試劑的敏感?相當高,未?應可用於?床Cipro殘?之檢測。在?確?方面,Cipro檢測盤之組內(intra-assay)與組間 (inter-assay)檢測變?值分別為5.82%和7.38%,顯示Cipro檢測盤?確?高。此外,本檢測盤對enrofloxacin和norfloxacin有較高的反應?外,對其餘抗菌劑皆小於0.2%。

英文摘要

The aim of this study is to develop a simple, rapid, and reliable enzyme-linked immunosorbent assay (ELISA) for detecting the residues of ciprofloxacin in the edible animal tissues. By the N-hydroxysuccinimide ester method, ciprofloxacin was conjugated with carrier proteins, HSA and HRP, respectively. Furthermore, we successfully used HPLC with UV and fluorescence detectors to detect ciprofloxacin-HSA conjugated protein. In the production of ciprofloxacin polyclonal antibody, the antibody titer was reached over 65,536 fold after subcutaneously injected ciprofloxacin-HSA conjugated protein into New Zealand rabbits. After six boosters with ciprofloxacin-HSA conjugated protein, we collected antisera and detected antibody sensitivity. The lowest detection limit (LDL) in PBS was 0.78 ppb. Overwhelmingly, our developed ciprofloxacin ELISA kit seemed to have very high sensitivity. At the same time, ciprofloxacin ELISA kit appeared to their sufficient sensitivity for ciprofloxacin residue detection in differnet biological matrices. The coefficient variation values of the intra-assay and inter-assay of the ciprofloxacin ELISA kit was 5.82% and 7.38%. In the other matrix (milk, FBS, fish, pork, chicken, shrimp, and beef), the LDL was 1.08, 1.37, 0.83, 1.1, 0.88, 1.32, and 1.14 ppb, respectively. In the 50% cross-reactivety for non-Cipro antibiotics was below 0.2%, except the to enrofloxacin and norfloxacin. Therefore, our developed ciprofloxacin ELISA kit had very good precision. According to these results, our developed ciprofloxacin ELISA kit seemed to be a simple, rapid, and reproducible tool for ciprofloxacin residue detection for the different animal productions.

相關文獻