文章詳目資料

防蝕工程 EIScopus

  • 加入收藏
  • 下載文章
篇名 鍋爐二次過熱器出口爐管TP-304之劣化分析
卷期 7:3
並列篇名 Metallurgical Examination of A Failed Secondary TP-304 Superheater Tube in Boilerc
作者 鄭錦榮王家瓚謝運華
頁次 10-20
關鍵字 CreepingOil Ash CorrosionSecondary Superheater Tube潛變油灰腐蝕二次過熱熱器出口管EI
出刊日期 199309

中文摘要

本文主要探討鍋爐二次過熱出口爐管TP-304劣化,利用電子顯微鏡觀察破孔斷面金相組織及探討腐蝕之影響因素,破損劣化主要原因是由於油灰腐蝕與潛變現象,導致管壁外層氧化物損耗。

英文摘要

A metallurgical exmination was performed on a failed Secondany superheater tube from steam Power Station. The prupose of the examination was to determine the probable cause of the failed secondary superheater tube. The failure of the stainless steel secondary superheater tube was attributed to oil ash corrosion and creeping which resulted in stress ruptrure of the tube metal due to loss of oxided layer material on the external side of the tube.

相關文獻