篇名 基於故障相電壓功率譜的串補輸電線路故障識別
卷期 32:1
並列篇名 FAULT RECOGNITION FOR EHV/UHV TRANSMISSION LINE WITH SERIES CAPACITORS BASED ON POWER SPECTRUM OF FAULTY PHASE VOLTAGE
作者 商立群陳鴻誠陳文淵
頁次 091-096
關鍵字 超高壓串聯電容補償輸電線路暫態性故障永久性故障功率譜EHVseries capacitor compensative transmission linetemporary faultpermanent faultpower spectrumEIScopusTSCI
出刊日期 201703

中文摘要

超高壓串補輸電線路在單相暫態性接地故障時,故障相恢復電壓包含工頻 分量、接近於工頻的分量以及低頻分量,其功率譜有3 條譜線;而永久性接地 故障時,故障相恢復電壓僅由工頻分量、低頻分量疊加而成,其功率譜有2 條 譜線。據此針對串補輸電線路提出一種基於故障相恢復電壓功率譜的單相接地 故障識別方法,該方法利用故障相電壓各分量功率譜的譜線分佈來識別暫態性 故障和永久性故障,EMTP 模擬驗證了該方法的準確性和可行性。

英文摘要

The recovery voltage of the fault phase during occurrences of singlephase temporary faults in EHV/UHV transmission lines with series capacitors is composed of the components of power frequency, approximate power frequency, and low frequency. The power spectrum of the recovery voltage possesses three spectral lines. However, the recovery voltage of singlephase permanent fault only contains power frequency and low frequency components, and its power spectrum possesses two spectral lines. On this basis, an identification method of temporary and permanent single-phase earth fault was proposed for the transmission lines with series capacitors. Simulation results showed that the proposed method based on power spectrum of fault phase recovery voltage was accurate and feasible.