文章詳目資料

藥物食品檢驗局調查研究年報

  • 加入收藏
  • 下載文章
篇名 Determination of higenamine in plasma and urine by high-performance liquid chromatography with electrochemical detection
卷期 13
作者 Chi-Fang LoChi-Ming Chen
頁次 010-016
關鍵字 TSCI
出刊日期 199509

中文摘要

英文摘要

A method for the determination of higenamine in plasma and urine based on high-performance liquid chromatography (HPLC) with electrochemical detection was developed. The plasma or urine sample was treated by adsorption with acidic alumina and then higenamine was released by acid treatment. HPLC was performed on an ODS column with a mobile phase of acetonitrile-0.1% phosphoric acid (9:91) and an electrochemical detector at an oxidation potential of 0.75 V. The lower limits of the assay for higenamine in plasma and urine were 2.645 and 10.58 ng/ml, respectively. The recoveries of higenamine after alumina treatment in rabbit plasma and urine were ca. 77.5 and 84.4%, respectively. Intra- and inter-day precision and accuracy reported as coefficients of variation in plasma and urine were less than 1%. The application oi the assay was demonstrated successfully by the determination of the concentration of higenamine in rabbit plasma and urine samples after closes of higenamine hydrochloride at 20 mg/kg intravenously and 50 mg/kg orally.

本卷期文章目次

關鍵知識WIKI

相關文獻